Release 4

Observation-example-satO2

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

This is the narrative for the resource. See also the XML, JSON or Turtle format. This example conforms to the profile Observation.


Generated Narrative with Details

id: satO2

meta:

identifier: o1223435-10

partOf: Procedure/ob

status: final

category: Vital Signs (Details : {http://terminology.hl7.org/CodeSystem/observation-category code 'vital-signs' = 'Vital Signs', given as 'Vital Signs'})

code: Oxygen saturation in Arterial blood (Details : {LOINC code '2708-6' = 'Oxygen saturation in Arterial blood', given as 'Oxygen saturation in Arterial blood'}; {LOINC code '59408-5' = 'Oxygen saturation in Arterial blood by Pulse oximetry', given as 'Oxygen saturation in Arterial blood by Pulse oximetry'}; {urn:iso:std:iso:11073:10101 code '150456' = '150456', given as 'MDC_PULS_OXIM_SAT_O2'})

subject: Patient/example

effective: Dec 5, 2014 9:30:10 AM

value: 95 % (Details: UCUM code % = '%')

interpretation: Normal (applies to non-numeric results) (Details : {http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation code 'N' = 'Normal', given as 'Normal'})

device: DeviceMetric/example

ReferenceRanges

-LowHigh
*90 % (Details: UCUM code % = '%')99 % (Details: UCUM code % = '%')

 

 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.