Таблицы соответствий для ресурса device (см. Mappings to Other Standards for further information & status).

Device
    identifierFiveWs.identifier
    udiCarrierFiveWs.identifier
        deviceIdentifierFiveWs.what[x]
    statusFiveWs.status
    statusReasonFiveWs.status
    distinctIdentifierFiveWs.what[x]
    manufacturerFiveWs.what[x]
    manufactureDateFiveWs.what[x]
    expirationDateFiveWs.what[x]
    lotNumberFiveWs.what[x]
    serialNumberFiveWs.what[x]
        typeFiveWs.what[x]
    modelNumberFiveWs.what[x]
    partNumberFiveWs.what[x]
        versionFiveWs.what[x]
        componentFiveWs.what[x]
    patientFiveWs.subject[x]
    ownerFiveWs.source
    contactFiveWs.source
    locationFiveWs.where[x]
    urlFiveWs.where[x]
DeviceDevice
    identifier.id
    udiCarrier.id and .code
        deviceIdentifierRole.id.extension
        issuerRole.id.root
        jurisdictionRole.scoper
        carrierAIDCRole.id.extension
        carrierHRFRole.id.extension
        entryTypeNA
    status.statusCode
    distinctIdentifier.lotNumberText
    manufacturer.playedRole[typeCode=MANU].scoper.name
    manufactureDate.existenceTime.low
    expirationDate.expirationTime
    lotNumber.lotNumberText
    serialNumber.playedRole[typeCode=MANU].id
        type.playedRole[typeCode=MANU].code
    modelNumber.softwareName (included as part)
    partNumber.playedRole[typeCode=MANU].id
    patient.playedRole[typeCode=USED].scoper.playedRole[typeCode=PAT]
    owner.playedRole[typeCode=OWN].scoper
    contact.scopedRole[typeCode=CON].player
    location.playedRole[typeCode=LOCE].scoper
    url.telecom
    note.text
    safetyNA

UDI is a unique numeric or alphanumeric code that consists of two parts: (1) a device identifier (DI), a mandatory, fixed portion of a UDI that identifies the labeler and the specific version or model of a device, and (2) a production identifier (PI), a conditional, variable portion of a UDI that identifies one or more of the following when included on the label of a device: (2a) the lot or batch number within which a device was manufactured; (2b) the serial number of a specific device; (2c) the expiration date of a specific device; (2d) the date a specific device was manufactured; (2e) the distinct identification code required by §1271.290(c) for a human cell, tissue, or cellular and tissue-based product (HCT/P) regulated as a device.

Device
    identifierСерийный номер, который является компонентом производственного идентификатора (PI), условной, переменной части UDI. Значение identifier.type должно быть установлено в "SNO" (серийный номер), а элемент system оставлен пустым.
    definition
    udiCarrier
        deviceIdentifierThe device identifier (DI), a mandatory, fixed portion of a UDI that identifies the labeler and the specific version or model of a device.
        issuerAll UDIs are to be issued under a system operated by an Jurisdiction-accredited issuing agency.
GS1 DIs:
http://hl7.org/fhir/NamingSystem/gs1
HIBCC DIs:
http://hl7.org/fhir/NamingSystem/hibcc
ICCBBA DIs for blood containers:
http://hl7.org/fhir/NamingSystem/iccbba-blood
ICCBA DIs for other devices:
http://hl7.org/fhir/NamingSystem/iccbba-other
        jurisdiction
        carrierAIDCA unique device identifier (UDI) on a device label a form that uses automatic identification and data capture (AIDC) technology.
        carrierHRFA unique device identifier (UDI) on a device label in plain text
        entryType
    status
    statusReason
    distinctIdentifierНомер партии, в рамках которой было произведено устройство - который является компонентом производственного идентификатора (PI), условной, переменной части UDI.
    manufacturerN/A
    manufactureDateДата производства конкретного устройства - являющаяся компонентом производственного идентификатора (PI), условной, переменной части UDI. Для FHIR синтаксис datetime должен быть преобразован в формат YYYY-MM-DD[THH:MM:SS]. Если указан час, то минуты и секунды должны иметь значение "00".
    expirationDateДата истечения срока годности конкретного устройства - является компонентом производственного идентификатора (PI), условной, переменной части UDI. Если указан час, то минуты и секунды должны иметь значение "00".
    lotNumberНомер партии, в рамках которой было произведено устройство - который является компонентом производственного идентификатора (PI), условной, переменной части UDI.
    serialNumber
    deviceName
        name
        type
    modelNumber
    partNumber
    type
    specialization
        systemType
        version
    version
        type
        component
        value
    property
        type
        valueQuantity
        valueCode
    patient
    owner
    contact
    location
    url
    note
    safety
    parent